LinkSprite low-cost narrowband powerline communication module  move serial data over the power line network at a speed of 500 bps, and achieves the target of replacing serial cables by the ubiquitous power line network.

It can work on AC 220V/110V, 50Hz/60Hz, or DC line.

 

Specification:

 

  • Voltage: 220V/110V AC or 12V-16V DC
  • TTL UART interface data rate: 19200 bps
  • Interface: TTL UART, RXD, TXD
  • Coomunication powerline: 220V/110V, 50Hz/60Hz, DC, or no power
  • Communication Distance: 1000 meters (depends on the powerline enviroment)
  • Frame Length: <=20 Bytes
  • Carrier frequency: 290KHz/125Khz
  • Modulation: narrow band
  • Working temperature: -20 degree C to +70 degree C
  • Size: 6 cm X 4.5 cm X 2 cm (L X W X H)
 
Application:
 
  • AMR
  • Industry manufacture and control
  • Safeguard, fire alarm, smoke alarm
  • Collect and transmit instrument data
  • Safeguard and monitor
  • Home automation
  • Parking Meters
 
Headers Illustations:
 
 
 
 
 
+5VOUT has a current limit of 500mA.
 
When there is no AC voltage, VHH can supply power to the module, which ranges from +12V to +16V DC.
 

Download:

Product Reviews

Write Review

  1. Working fine!

    Posted by Alberto García on 15th Jun 2017

    Our first tests are showing better results that we could wait first. Very good behaviour over long distances.

  2. I CAN´T MAKE THE MODULE WORK

    Posted by Xavier Enrique Torres Zamudio on 5th Jun 2017

    Hi, this is the second time that I write this here, but I had not gotten an answers. I expect your respond soon. Thanks again.

  3. I CAN´T MAKE THE MODULE WORK

    Posted by Xavier Enrique Torres Zamudio on 1st Jun 2017

    Hello, I´m from Mexico City but for some reason I haven´t been able to connect with the module, I have tried everything that says in the "User Manual". I tried to communicate with the PLC module via VHH-GND using 14.5 VDC using XCTU versión 6.3.8 and nothing happened and my machine is running Windows. I don´t know what else to do, here in Mexico there is a signal for homes of 127 VAC , 60Hz. I expect you could answer me soon please. Thanks.